Á¦Ç° Ư¡ |
°ø°£È¿À²¼ºÀ» ³ôÀÎ ½½¸²Çü 19¡± Rack system(1 HU)À¸·Î ±¸¼º. ÇÑ °³ÀÇ ·¢½Ã½ºÅÛ´ç 16ä³ÎÀÇ ¸ÖƼÆã¼Ç °¥¹Ù´ÐÀý¿¬ ¾Æ³¯·Î±×ÀԷ°ú 64ä³ÎÀÇ µðÁöÅÐÀÔ·Â. 19-bit ºÐÇØ´É°ú 1000Hz »ùÇøµÀ¸·Î Carrier frequency¹æ½ÄÀÇ ½ºÆ®·¹ÀÎ, LVDTÃøÁ¤
|
|
»ó¼¼¼³¸í |
e.rack slimlineÀº °ø°£È¿À²¼ºÀ» ³ôÀÎ 19-inch(1 HU) Rack system·Î µðÀÚÀÎµÈ Á¦Ç°ÀÔ´Ï´Ù. ´ÜÁö ÇÑ °³ÀÇ ·¢½Ã½ºÅÛÀ¸·Î 16ä³ÎÀÇ ¸ÖƼÆã¼Ç °¥¹Ù´ÐÀý¿¬ ¾Æ³¯·Î±×ÀԷ°ú 64ä³ÎÀÇ µðÁöÅÐÀÔ·ÂÀÌ °¡´ÉÇÕ´Ï´Ù. 19-bit ºÐÇØ´É°ú 1000Hz »ùÇøµÀ¸·Î Carrier frequency¹æ½ÄÀÇ ½ºÆ®·¹ÀÎ, LVDTÃøÁ¤ÀÌ °¡´ÉÇÕ´Ï´Ù
|
|
e.rack A1-16 slimline General Purpose Measurin Unit |
 |
 |
|
 |
| Plug in Unit | |
|
|
| |
|
16 general prupose analog input channels Voltage, current, resistance, thermocouple, Pt100, Pt1000, bridges |
 |
High resolution fast A/D conversion 19 bit resolution at 1000 samples/s per channel |
 |
Signal conditioning Linearization, digital filtering, averaging, minimum/maximum storage, arithmetic, alarm |
 |
RS 485 fieldbus interface Profibus-DP, Modbus RTU, ASCII |
 |
|
| |
|
|
|
|
|
e.rack A3-16 slimline Multi-Channel Voltage Unit |
 |
 |
|
 |
| Plug in Unit | |
|
|
| |
|
16 analog input channels Difference voltage |
 |
High resolution 19 bit resolution at 100 samples/s per channel (total 1600/s) |
 |
Signal conditioning Linearization, digital filtering, averaging, minimum/maximum storage, arithmetic, alarm |
 |
RS 485 fieldbus interface Profibus-DP, Modbus RTU, ASCII |
 |
|
| |
|
|
|
|
|
e.rack A4-16 slimline Multi-Channel Thermocouple and Voltage Unit |
 |
 |
|
 |
| Plug in Unit | |
|
|
| |
|
16 analog, high speed, galvanic isolated channels Thermocouple, 19 bit at 100 samples/s |
 |
Cold junction compensation Integrated CJC each input |
 |
Dynamic linearization Optimised linearization for the types B, E, J, K, L, N, R, S, T, U |
 |
Signal conditioning Linearization, digital filtering, averaging, minimum/maximum storage, arithmetic, alarm |
 |
RS 485 fieldbus interface Profibus-DP, Modbus RTU, ASCII |
 |
|
| |
|
|
|
|
|
e.rack A5-16 slimline Multi-Channel RTD (Pt100/Pt1000) and Resistance Unit |
 |
 |
|
 |
| Plug in Unit | |
|
|
| |
|
16 analog input channels Pt100, Pt1000 and resistance |
 |
Excellent temperature stability e.g. Pt100: 0.05 ¡ÆC at -20 to +60 ¡ÆC environment temperature of the e.rack slimline |
 |
Signal conditioning Linearization, digital filtering, averaging, minimum/maximum storage, arithmetic, alarm |
 |
RS 485 fieldbus interface Profibus-DP, Modbus RTU, ASCII |
 |
|
| |
|
|
|
|
|
e.rack A6-16 slimline Carrier Frequency Bridge Unit |
 |
 |
|
 |
| Plug in Unit | |
|
|
| |
|
16 universal bridge inputs Strain gauge full and half bridges, inductive bridges, LVDT |
 |
High resolution fast A/D conversion 19 bit resolution at 500 samples/s per channel |
 |
1 analog output per channel +/- 10 V/100 Hz, each variable signal selectable, e.g. maximum or envelope curve |
 |
Signal conditioning Linearization, digital filtering, averaging, minimum/maximum storage, envelope curve, arithmetic, alarm |
 |
RS 485 fieldbus interface Profibus-DP, Modbus RTU, ASCII |
 |
|
| |
|
|
|
|
|
e.rack D1-64 slimline General Purpose Digital Unit |
 |
 |
|
 |
| Plug in Unit | |
|
|
| |
|
64 configurable digital inputs/outputs Status I/O, process or host controlled |
 |
Up to 32 frequency inputs Chronos method (simultaneous edge counting and cycle time measurement) up to 2 MHz |
 |
Up to 32 counter inputs Quadrature counter, up/down counter, up to 400 kHz |
 |
RS 485 fieldbus interface Profibus-DP, Modbus RTU, ASCII |
 |
|
| | |
 |
|
|
|