E.bloxx systemÀº ´Ù¾çÇÑ ¾Æ³¯·Î±× ¹× µðÁöÅÐ ÀÔÃâ·Â½ÅÈ£ÀÇ µ¥ÀÌÅͼöÁý.Á¦¾î¸¦À§ÇÑ ÃÖÀûÀÇÇÁ·Î¼¼½º·Î °í¾È¼³°èµÇ¾ú½À´Ï´Ù. ¸ðµç ¾Æ³¯·Î±× ¹× µðÁöÅнÅÈ£´Â ºü¸£°í Á¤¹ÐÇÏ°Ô ÃøÁ¤µÇ¾îÁö¸ç ¸ðµâ°£ RS-485 ÀÎÅÍÆäÀ̽º´Â À¯Àú°£ À¶Å뼺ÀÖ´Â ¼³°è¸¦ µ½½À´Ï´Ù.
>>¸ðµâº° 100Hz/1000Hz/5000Hz ´Ù¾çÇÑ »ùÇøµ¼Óµµ¸¦ ¼±Åð¡´É
>>½ºÆ®·¹ÀÎ ¹× ¿ÂµµÃøÁ¤½Ã ¸Å¿ì³ôÀº Á¤È®µµ¿Í ADCºÐÇØ´É 24-Bit(½ÇÁ¦»ç¿ë¿µ¿ª 19-Bit)
>>½ºÄÉÀϸµ,µðÁöÅÐÇÊÅÍ,Æò±Õ°ª,ÃÖ´ë/ÃÖ¼Ò°ªÀúÀå,¾Ë¶÷µî ½ÅÈ£ÀÇ ÄÁµð¼Å´×
>>°¢ ¸ðµâÀº Å×½ºÆ®ÄÜÆ®·ÑÀ» À§ÇÑ Profibus-DP, Modbus-RTU, ASCII µîÀÇ ÇÁ·ÎÅäÄÝÁö¿ø.
>>E.bloxx System Àº »ê¾÷ȯ°æ¿¡ ÀûÇÕÇϵµ·Ï ¼³°èµÇ¾î ¸ðµâ°£ GalvanicÀý¿¬ ¹× ³ÐÀº ¿ÂµµÈ¯°æ¿¡ ´ëÀÀ.

| e.bloxx Á¦Ç°»ó¼¼¼³¸í |
|
| ¾Æ·¡ÀÇ e.bloxx Á¦Ç°µéÀÇ ¼³¸í ¾Æ·¡¿¡ ÷ºÎµÇ¾î ÀÖ´Â ºê·Î¼Å ¹× ¸Þ´º¾óÀ» Âü°íÇϽþî ÀûÇÕÇÑ ½Ã½ºÅÛÀ» ¼³°èÇϼ¼¿ä!! |
|
|
|
e.bloxx A1 Àü¾Ð,Àü·ù,ÀúÇ×,Ãø¿ÂÀúÇ×,¿Âµµ, ºê¸®Áö µî À¯´Ï¹ö¼È ÀԷ¸ðµâ |
 |
 |
|
 |
| e.bloxx A1-1 | |
|
|
| |
|
1, 4 or 8 universal input channels Voltage, current, resistance, Pt100, Pt1000, thermocouples, meaurement bridges |
 |
1 digital input per channel Status, reset |
 |
1 solid state relay output per channel Status, alarm, threshold, tolerance band |
 |
ADC-conversion and signal conditioning with 19 bit up to 1000/s Linearization, digital filter, average, scaling, min/max memory, arithmetics |
 |
RS 485 fieldbus interface Profibus-DP, Modbus-RTU, ASCII |
 |
|
| |
|
|
|
|
|
e.bloxx A2 °í¼Ó»ùÇøµ Àü¾Ð,Àü·ù,ICP,strain gauge sensors ÀԷ¸ðµâ |
 |
|
|
|
 |
| e.bloxx A2-1 | |
|
|
| |
|
1 general purpose analog input channel strain gauge, piezo resistive bridges, and ICP sensors, voltage, current |
 |
1 digital input and 1 digital output Status, zero balance, memory reset, alarm, limit value, tolerance band |
 |
Signal conditioning Linearization, digital filtering, averaging, scaling, minimum/maximum store, true RMS value, arithmetic |
 |
TEDS functionality Reading of Transducer Electronic Data Sheet from a TEDS sensor module and setup of the A2 internals automatically (IEEE 1451.4 Class 2) |
 |
RS 485 fieldbus interface Modbus-RTU, ASCII, and Local Bus to Test Controller |
 |
|
| |
|
|
|
|
|
e.bloxx A3 Àü¾Ð,Àü·ù ¸ÖƼä³Î ÀԷ¸ðµâ |
 |
|
|
|
 |
| e.bloxx A3-1 | |
|
|
| |
|
4 or 16 galvanic isolated voltage / current input channels Differential voltage, current (with e.bloxx Terminal 4C), galvanically isolated 100VDC |
 |
Sample rate 100/s with 4 active channels Module sample rate 400/s |
 |
1 digital input and 1 digital output Status, reset, alarm, threshold, tolerance band |
 |
ADC-conversion and signal conditioning with 19 bit Linearization, digital filter, average, scaling, min/max memory, arithmetics |
 |
RS485 fieldbus interface Profibus-DP, Modbus-RTU, ASCII |
 |
|
| |
|
|
|
|
|
e.bloxx A4TC ¸ÖƼä³Î ¿Âµµ(TC)ÀÔ·Â ¸ðµâ |
 |
|
|
|
 |
| e.bloxx A4-1TC | |
|
|
| |
|
4 or 16 galvanic isolated Thermocouple input channels Thermocouples, voltages +/- 80 mV |
 |
Dynamic linearization Optimized use of base points for type B, E, J, K, L, N, R, S, T, U, import of individual curves |
 |
ADC-conversion and signal conditioning with 19 bit and up to 100/s Linearization, digital filter, average, scaling, min/max memory, arithmetics |
 |
RS485 fieldbus interface Profibus-DP, Modbus-RTU, ASCII |
 |
|
| |
|
|
|
|
|
e.bloxx A5 Á¤¹Ð±Þ Pt100/Pt1000 ÀԷ¸ðµâ |
 |
|
|
|
 |
| e.bloxx A5-1 | |
|
|
| |
|
RTD input module Pt100/Pt1000, resistance in 2, 3 or 4 wire |
 |
1 digital input Status, reset |
 |
1 digital output Alarm, threshold, tolerance band |
 |
ADC-conversion and signal conditioning with 19 bit Linearization, digital filter, average, scaling, min/max memory, arithmetics |
 |
RS485 fieldbus interface Profibus-DP, Modbus-RTU, ASCII |
 |
|
| |
|
|
|
|
|
e.bloxx A5CR 2-ä³Î ±ØÀú¿Â(Cryo)¼¾¼ ÀԷ¸ðµâ |
 |
|
|
|
 |
| e.bloxx A5-1CR | |
|
|
| |
|
2 Input channels for Cryo sensors e.g. Type Cernox or TVO |
 |
Sensor excitation 8 ¥ìAeff only to avoid self heading of the sensor |
 |
Individual linearization of the sensor characteristics Sensor specific linearization by using 64 nodes and archive in a sensor data file (import function). |
 |
1 digital input, 1 digital output Status, alarm, limit value, tolerance band |
 |
RS 485 fieldbus interface Profibus-DP, Modbus-RTU, ASCII |
 |
|
| |
|
|
|
|
|
e.bloxx A6CF Á¤¹Ð±Þ ½ºÆ®·¹ÀÎ(Bridge) ÀԷ¸ðµâ |
 |
|
|
|
 |
| e.bloxx A6-1CF | |
|
|
| |
|
Universal bridge input Strain gauge full-, half- and quarter bridges, inductive bridges, LVDT etc. |
 |
1 digital input and 1 digital output Definition of the functionality (e.g. tare, alarm, limit value, tolerance band) |
 |
1 analog output ¡¾ 10 V, each variable signal selectable, e.g. maximum or envelope curve |
 |
Signal conditioning Linearization, digital filter, scaling, taring, minimum/maximum store, envelope curve, arithmetic, alarm, limit value, tolerance band |
 |
RS 485 fieldbus interface Profibus-DP, Modbus-RTU, ASCII |
 |
|
| |
|
|
|
|
|
e.bloxx A6-2CF Á¤¹Ð±Þ ½ºÆ®·¹ÀÎ(Bridge) ÀԷ¸ðµâ |
 |
|
|
|
 |
| e.bloxx A6-2CF | |
|
|
| |
|
Universal carrier frequency sensor connection Strain gauges full, half and quarter bridges, inductive bridges, LVDT |
 |
6 digital inputs and 4 digital outputs Functions definable, e.g. memory delete, frequency measurement, counter, alarm, threshold, tolerance band, status |
 |
2 analog outputs +/- 10 V, any variable attributable, e.g. netto and envelope curve |
 |
ADC-conversion and signal conditioning with 19 bit and 5000/s Linearization, digital filter 4th pole, scaling, tare, min/max memory, run/hold, envelope curve, arithmetics, alarm, threshold, tolerance band |
 |
RS485 fieldbus interface Profibus-DP, Modbus-RTU, ASCII |
 |
|
| |
|
|
|
|
|
e.bloxx A9 ¾Æ³¯·Î±× ¸ÖƼ Ãâ·Â ¸ðµâ |
 |
|
|
|
 |
| e.bloxx A9-1 | |
|
|
| |
|
4 analog outputs Voltage +/- 10V and current 4..20mA selectable |
 |
16 bit DAC Conversion rate up to 1000/s |
 |
1 digital input and 1 digital output Status, tara, reset, alarm, threshold, tolerance band |
 |
Signal conditioning Scaling, min/max memory, arithmetics |
 |
RS485 fieldbus interface Profibus-DP, Modbus-RTU, ASCII |
 |
|
| |
|
|
|
|
|
e.bloxx D1 µðÁöÅÐ ÀÔÃâ·Â ¸ðµâ(PWM½ÅÈ£ ÃøÁ¤ ¹× Ãâ·Â) |
 |
|
|
|
 |
| e.bloxx D1-1 | |
|
|
| |
|
8 to 32 digital in/outputs freely configurable |
 |
Status in-/output Process or host controlled |
 |
Frequence in-/output Chronos method for precise and fast frequence measurement up to 2 MHz, frequency and PWM output |
 |
Counter input Quadrature counter, Up/Down counter up to 400 kHz |
 |
RS485 fieldbus interface Profibus-DP, Modbus-RTU, ASCII |
 |
|
| |
|
|
|
|
|
e.bloxx D2 ¸±·¹ÀÌ Ãâ·Â ¸ðµâ |
 |
|
|
|
 |
| e.bloxx D2-1 | |
|
|
| |
|
4 relay outputs 2 closing contacts and 2 switchable contacts |
 |
Switching of electrical power 230 VAC / 3 A, 30 VDC / 3 A |
 |
Many operations Expected mechanical life-span: 50,000,000 cycles |
 |
RS485 fieldbus interface Profibus-DP, Modbus-RTU, ASCII |
 |
|
| |
|
|
|
|
|
e.bloxx D3 CAN and serial interface ¸ðµâ |
 |
|
|
|
 |
| e.bloxx D3 | |
|
|
| |
|
e.bloxx D3-CAN - CAN input and output CAN node 2.0A / 2.0B ref. to ISO 11898 |
 |
e.bloxx D3-COM - RS-485 und RS-232 Master For connecting of serial devices and fieldbus slaves, standard protocol Modbus-RTU, others on request |
 |
e.bloxx D3-SSI - RS-422 Master For connection absolute encoders (e.g. angle, displacement) with SSI (serial synchrony interface) |
 |
6 digital inputs and 4 digital outputs Definition of functions like status, alarm or counter |
 |
RS-485 fieldbus (slave) interface Profibus-DP, Modbus-RTU, ASCII |
 |
|
| |
|