ISO-Channel technology provides ¡¾500 V galvanic isolation channel-to-channel for all analog input signals and to the host computer ...guarantees noise immunity
Input gains of 1, 8, 16, and 32 with input ranges of ¡¾10 V to support the following effective ranges: ¡¾10 V, ¡¾1.25 V, ¡¾0.625 V, ¡¾0.3125 V ...allows maximum flexibility for any signal input
ADVANCED SAMPLING MODES
Sampling frequency up to 4800Hz
Continuously paced analog input operations
Software-programmable trigger type (software or external digital trigger) to start analog input operations
Channel Gain list allows measurement of any combination of channels/gains
ISOLATED DIGITAL I/O
8 opto-isolated digital input lines
8 opto-isolated digital output lines; the outputs are solid-state relays that operate from ¡¾30 V at currents up to 400 mA (peak) AC or DC data stream for correlating analog and digital measurements
Digital I/O galvanically isolated to 250 V
Read the digital input port through the analog input
DT9824
The DT9841 is a real-time USB data acquisition module with embedded DSP for high-accuracy sound and vibration testing. It features full data acquisition capability: eight 24-bit analog inputs, two 24-bit analog outputs, 24 lines of digital I/O, and three 32-bit counter timers.
Key Features:
VOLTAGE INPUTS •4, simultaneous, 24-bit analog input channels •ISO-Channel technology provides ¡¾500 V galvanic isolation channel-to-channel for all analog input signals and to the host computer ...guarantees noise immunity •Input gains of 1, 8, 16, and 32 with input ranges of ¡¾10 V to support the following effective ranges: ¡¾10 V, ¡¾1.25 V, ¡¾0.625 V, ¡¾0.3125 V ...allows maximum flexibility for any signal input ADVANCED SAMPLING MODES •Sampling frequency up to 4800Hz •Continuously paced analog input operations •Software-programmable trigger type (software or external digital trigger) to start analog input operations •Channel Gain list allows measurement of any combination of channels/gains ISOLATED DIGITAL I/O •8 opto-isolated digital input lines •8 opto-isolated digital output lines; the outputs are solid-state relays that operate from ¡¾30 V at currents up to 400 mA (peak) AC or DC data stream for correlating analog and digital measurements •Digital I/O galvanically isolated to 250 V •Read the digital input port through the analog input
Item
Description
DT9824
High Accuracy USB DAQ Module
DT9824-OEM
High Accuracy USB DAQ Module, board-level (OEM) version
Accessories
EP333
Shielded cable (2m) with 37-pin connectors. Used to connect a DAQ module or accessory panel to an STP37 screw terminal panel.
EP379
Dual-Rack Mount Kit
EP380
Single-Rack Mount Kit
STP37
Screw terminal panel for connecting I/O signals. Requires EP333 cable to connect STP37 with DAQ module or accessory panel.
Measure Foundry¢ç
Measure Foundry is an open, powerful application builder for test and measurement systems. Easily and quickly create complex applications without writing code.
Additional Software:
- The free Dynamic Signal Analyzer application allows you to perform dynamic signal processing operations on a DT9840 Series module without programming. - Measure Foundry allows you to stream data from the DT9840 series module without using Visual Studio or Code Composer. Measure Foundry allows you to build complex test and measurement applications easily without writing code.
EP333
2-meter shielded cable with two 37-pin connectors. Used to connect to an STP37 screw terminal panel.
EP379
Dual-Rack mount kit
EP380
Dual-Rack mount kit
STP37
Screw terminal panel for connecting I/O signals from the EP353 or EP356 accessory panel.
»óÈ£: (ÁÖ)À妽ºÆ¼¿¥ I ÁÖ¼Ò: 16514, °æ±âµµ ¼ö¿ø½Ã ¿µÅ뱸 ¹ýÁ¶·Î 25, ±¤±³ SK VIEW Lake, Aµ¿ 1602È£ (³»¹æ°´: 24Ãþ ȸÀÇ½Ç »çÀü¿¹¾à) »ç¾÷ÀÚµî·Ï¹øÈ£: 214-03-16174 I ´ëÇ¥ÀÚ: Á¶Àκ¹ I ´ëÇ¥: 031-895-4370 Copyright @ 2000-2020 INDEXTM Corporation All Right Reserved º» ȨÆäÀÌÁöÀÇ ¹«´Üº¹Á¦¸¦ ºÒÇãÇÔ INDEXTM Corporation A-1602, SK VIEW Lake Tower, 25, Beopjo-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16514, Korea.