MultiCon CMC-141 µ¥ÀÌÅͷΰÅ


4ä³Î¿¡¼­ ÃÖ´ë 72ä³Î ¸ðµâÈ®Àå°¡´É
Àü¾Ð,Àü·ù(0/4-20 mA or 0/1-5V or 0/2-10V),½á¸ÓÄ¿ÇÃ, RTD,
Ä«¿îÅÍ, À¯·®(¼ø½Ã/Àû»ê), µðÁöÅÐ ÀÔ·Â ¹× Ãâ·Â
ÅÍÄ¡½ºÅ©¸° 5.7ÀÎÄ¡ TFT LCD Display
1.5 GB ³»ºÎ¸Þ¸ð¸®
144 x 144 Ædzڸ¶¿îÆ®Çü
µ¿¿µ»óº¸±â



MultiCon CMC‑141 Àº ´Ù¾çÇÑ ¸ÖƼ½ÅÈ£ÀԷ»Ӹ¸ ¾Æ´Ï¶ó ¸±·¹ÀÌ, ¾Æ³¯·Î±×, µðÁöÅеîÀÇ Ãâ·Â±â´ÉµéÀ» Æ÷ÇÔÇÑ
Á¦¾î±â´É(PID, ON/OFF, ½Ã°£ ¹× ÇÁ·ÎÇÊ µî..)À» °®´Â ´Ù¿ëµµÀÇ ÄÄÆÑÆ® ¸ÖƼ·Î±ë + Á¦¾î±â·Î ¼³°è°¡´ÉÇÕ´Ï´Ù.


°ø±ÞÀü¿ø 19V ¡À 50V DC; 16V ¡À 35V AC or 85 ¡À 260V AC/DC
¼ÒºñÀü·Â  typical 25 VA; max. 35 VA
Ãâ·Â½ÅÈ£  24 analog (4-20 mA) or 36 relay (1A/250V) / 72 SSR outputs or 18 relay 5A/250V max.,
sensor supply: 24 V DC ¡¾ 5% (200 mA max. for current inputs)
ÃøÁ¤·¹ÀÎÁö  ÀԷ¸ðµâ¿¡ µû¸§
ÀԷ½ÅÈ£  up to 15 À¯´Ï¹ö¼ÈÀÔ·Â; ÃÖ´ë72 ¾Æ³¯·Î±×ÀÔ·Â (0/4-20 mA or 0/1-5V or 0/2-10V) ÃÖ´ë72 µðÁöÅÐÀÔ·Â
 36 ½á¸ÓÄ¿ÇÃ,18 RTD ÀÔ·Â.12 Ä«¿îÅÍ/ À¯·®°è/ ratemeter, 1 digital input 24V DC (available in standard,
 integrated with  PS3 or PS4 power supply module)
Åë½Å interface standard: RS-485 (Modbus RTU), 1 x USB Host; ETU version: 1 or 2 x USB Host, 1 x Ethernet 10 MB
; enhanced ACM version: 2 x RS-485, 1 x RS-485/232, 1 or 2 x USB Host, 1 x Ethernet 10 MB
º¸°ü¿Âµµ  -10¡ÆC ¡À +70¡ÆC (optional -20¡ÆC ¡À +70¡ÆC with PCB conformal coating)
·¹ÄÚµù ¼Óµµ  from 0,1 s to 24 h with resolution 0,1 s
³»Àå¸Þ¸ð¸®  1,5 GB
ÀÛµ¿¿Âµµ 0¡ÆC ¡À +50¡ÆC (optional -20¡ÆC ¡À +50¡ÆC with PCB conformal coating)
Àåºñ»çÀÌÁî  144 x 144 x 100 mm
Case panel mounting
Case material NORYL - GFN2S E1
Protection class IP 65 (front), available options: additional frame IP 65 for panel cut-out sealing, transparent door
STD-141; version with front USB: IP 40 or IP 54 (when fitted with STD-141 transparent door)
µð½ºÇ÷¹ÀÌ  5.7 inch graphic TFT, 16-bit colour, 320 x 240 pixels, with touch screen
ÆdzÚÄÆ »çÀÌÁî  137 x 137 mm
¼ÒÇÁÆ®¿þ¾î  Free DAQ Manager software for multichannel controller can be downloaded directly from section „Download¡±
¼³Ä¡±íÀÌ min. 102 mm
 

Gallery


Option configurator

Product code:
Slot P: power supply 19 - 50V DC, 16 - 35V AC; sensor supply 24V DC +/-5% (200mA max); digital inputs
1x 24V DC, optocoupled; communication interface: RS-485/Modbus RTU, USB device (service)
Slot P: power supply 85 - 260V AC/DC; sensor supply 24V DC +/-5% (200mA max); digital inputs 1x 24V DC
, optocoupled; communication interface: RS-485/Modbus RTU, USB device (service)
Slot D: no communication module (available for front USB host)
Slot D: port USB (rear)
Slot D: ACM communication module (RS-485, RS-485/232, USB Host, Ethernet)
Slot D: ETU communication module (USB Host, Ethernet)
Slot C: empty (E)
Slot C: 3 x universal input, isolated (UN3)
Slot C: 5 x universal input, isolated (UN5)
Slot C: 4 x voltage input + 4 x current input (UI4)
Slot C: 8 x voltage input + 8 x current input (UI8)
Slot C: 12 x voltage input + 12 x current input (UI12)
Slot C: 16 x voltage input (U16)
Slot C: 24 x voltage input (U24)
Slot C: 6 x 4-20 mA inputs, isolated (IS6)
Slot C: 16 x current input (I16)
Slot C: 24 x current input (I24)
Slot C: 4 x RTD input (RT4)
Slot C: 6 x RTD input (RT6)
Slot C: 4 x TC/mV input (TC4)
Slot C: 8 x TC/mV input (TC8)
Slot C: 12 x TC/mV input (TC12)
Slot C: 8 x digital input (D8)
Slot C: 16 x digital input (D16)
Slot C: 24 x digital input (D24)
Slot C: 2 x pulse input (universal counters), isolated (CP2)
Slot C: 4 x pulse input (universal counters), isolated (CP4)
Slot C: 2 x hourmeters, isolated (HM2)
Slot C: 4 x hourmeters, isolated (HM4)
Slot C: 2 x pulse input (flowmeters/ratemeters) + 2 x current input (FT2)
Slot C: 4 x pulse input (flowmeters/ratemeters) + 4 x current input (FT4)
Slot C: 2 x current input (flowmeters) + 2 x current input (FI2)
Slot C: 4 x current input (flowmeters) + 4 x current input (FI4)
Slot C: 4 x voltage inputs + 4 x current inputs + 8 x NTC inputs (UI4N8)
Slot C: 4 x voltage inputs + 4 x current inputs + 8 x digital inputs (UI4D8)
Slot C: 8 x voltage inputs + 8 x current inputs + 8 x NTC inputs (UI8N8)
Slot C: 8 x voltage inputs + 8 x current inputs + 8 x digital inputs (UI8D8)
Slot C: 8 x SPST relay 1A (R81)
Slot C: 12 x SPST relay 1A (R121)
Slot C: 4 x SPDT relay 5A (R45)
Slot C: 6 x SPDT relay 5A (R65)
Slot C: 8 x SSR output (S8)
Slot C: 16 x SSR output (S16)
Slot C: 24 x SSR output (S24)
Slot C: 2 x 4-20 mA outputs (IO2)
Slot C: 4 x 4-20 mA outputs (IO4)
Slot C: 6 x 4-20 mA outputs (IO6)
Slot C: 8 x 4-20 mA outputs (IO8)
Slot B: empty (E)
Slot B: 3 x universal input, isolated (UN3)
Slot B: 5 x universal input, isolated (UN5)
Slot B: 4 x voltage input + 4 x current input (UI4)
Slot B: 8 x voltage input + 8 x current input (UI8)
Slot B: 12 x voltage input + 12 x current input (UI12)
Slot B: 16 x voltage input (U16)
Slot B: 24 x voltage input (U24)
Slot B: 6 x 4-20 mA inputs, isolated (IS6)
Slot B: 16 x current input (I16)
Slot B: 24 x current input (I24)
Slot B: 4 x RTD input (RT4)
Slot B: 6 x RTD input (RT6)
Slot B: 4 x TC/mV input (TC4)
Slot B: 8 x TC/mV input (TC8)
Slot B: 12 x TC/mV input (TC12)
Slot B: 8 x digital input (D8)
Slot B: 16 x digital input (D16)
Slot B: 24 x digital input (D24)
Slot B: 2 x pulse input (universal counters), isolated (CP2)
Slot B: 4 x pulse input (universal counters), isolated (CP4)
Slot B: 2 x hourmeters, isolated (HM2)
Slot B: 4 x hourmeters, isolated (HM4)
Slot B: 2 x pulse input (flowmeters/ratemeters) + 2 x current input (FT2)
Slot B: 4 x pulse input (flowmeters/ratemeters) + 4 x current input (FT4)
Slot B: 2 x current input (flowmeters) + 2 x current input (FI2)
Slot B: 4 x current input (flowmeters) + 4 x current input (FI4)
Slot B: 4 x voltage inputs + 4 x current inputs + 8 x NTC inputs (UI4N8)
Slot B: 4 x voltage inputs + 4 x current inputs + 8 x digital inputs (UI4D8)
Slot B: 8 x voltage inputs + 8 x current inputs + 8 x NTC inputs (UI8N8)
Slot B: 8 x voltage inputs + 8 x current inputs + 8 x digital inputs (UI8D8)
Slot B: 8 x SPST relay 1A (R81)
Slot B: 12 x SPST relay 1A (R121)
Slot B: 4 x SPDT relay 5A (R45)
Slot B: 6 x SPDT relay 5A (R65)
Slot B: 8 x SSR output (S8)
Slot B: 16 x SSR output (S16)
Slot B: 24 x SSR output (S24)
Slot B: 2 x 4-20 mA outputs (IO2)
Slot B: 4 x 4-20 mA outputs (IO4)
Slot B: 6 x 4-20 mA outputs (IO6)
Slot B: 8 x 4-20 mA outputs (IO8)
Slot A: empty (E)
Slot A: 3 x universal input, isolated (UN3)
Slot A: 5 x universal input, isolated (UN5)
Slot A: 4 x voltage input + 4 x current input (UI4)
Slot A: 8 x voltage input + 8 x current input (UI8)
Slot A: 12 x voltage input + 12 x current input (UI12)
Slot A: 16 x voltage input (U16)
Slot A: 24 x voltage input (U24)
Slot A: 6 x 4-20 mA inputs, isolated (IS6)
Slot A: 16 x current input (I16)
Slot A: 24 x current input (I24)
Slot A: 4 x RTD input (RT4)
Slot A: 6 x RTD input (RT6)
Slot A: 4 x TC/mV input (TC4)
Slot A: 8 x TC/mV input (TC8)
Slot A: 12 x TC/mV input (TC12)
Slot A: 8 x digital input (D8)
Slot A: 16 x digital input (D16)
Slot A: 24 x digital input (D24)
Slot A: 2 x pulse inputs (universal counters), isolated (CP2)
Slot A: 4 x pulse input (universal counters), isolated (CP4)
Slot A: 2 x hourmeters, isolated (HM2)
Slot A: 4 x hourmeters, isolated (HM4)
Slot A: 2 x pulse input (flowmeters/ratemeters) + 2 x current input (FT2)
Slot A: 4 x pulse input (flowmeters/ratemeters) + 4 x current input (FT4)
Slot A: 2 x current input (flowmeters) + 2 x current input (FI2)
Slot A: 4 x current input (flowmeters) + 4 x current input (FI4)
Slot A: 4 x voltage inputs + 4 x current inputs + 8 x NTC inputs (UI4N8)
Slot A: 4 x voltage inputs + 4 x current inputs + 8 x digital inputs (UI4N8)D
Slot A: 8 x voltage inputs + 8 x current inputs + 8 x NTC inputs (UI8N8)
Slot A: 8 x voltage inputs + 8 x current inputs + 8 x digital inputs (UI8D8)
Slot A: 8 x SPST relay 1A (R81)
Slot A: 12 x SPST relay 1A (R121)
Slot A: 4 x SPDT relay 5A (R45)
Slot A: 6 x SPDT relay 5A (R65)
Slot A: 8 x SSR output (S8)
Slot A: 16 x SSR output (S16)
Slot A: 24 x SSR output (S24)
Slot A: 2 x 4-20 mA outputs (IO2)
Slot A: 4 x 4-20 mA outputs (IO4)
Slot A: 6 x 4-20 mA outputs (IO6)
Slot A: 8 x 4-20 mA outputs (IO8)
Options: no options (001)
Options: PCB conformal coating (00C)
Options: IP 65 frame (011)
Options: IP 65 frame + PCB conformal coating (01C)
Options: operating temperature -20¡ÆC ¡À +50¡ÆC including PCB conformal coating (081)
Options: front USB Host (0B1)
Options: front USB Host (IP 40) + PCB conformal coating (0BC)
Options: IP 65 + operating temperature -20¡ÆC ¡À +50¡ÆC including PCB conformal coating (0P1)
Options: front USB Host + operating temperature -20¡ÆC ¡À +50¡ÆC including PCB conformal
    coating (0K1)
   



  »óÈ£:  (ÁÖ)À妽ºÆ¼¿¥ I ÁÖ¼Ò: 16514, °æ±âµµ ¼ö¿ø½Ã ¿µÅ뱸 ¹ýÁ¶·Î 25, ±¤±³ SK VIEW Lake, Aµ¿ 1602È£ (³»¹æ°´: 24Ãþ ȸÀÇ½Ç »çÀü¿¹¾à)
  »ç¾÷ÀÚµî·Ï¹øÈ£: 214-03-16174  I  ´ëÇ¥ÀÚ: Á¶Àκ¹  I  ´ëÇ¥: 031-895-4370  
  Copyright @ 2000-2020 INDEXTM Corporation All Right Reserved
          º» ȨÆäÀÌÁöÀÇ ¹«´Üº¹Á¦¸¦ ºÒÇãÇÔ
           INDEXTM Corporation  A-1602, SK VIEW Lake Tower, 25, Beopjo-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16514, Korea.