DT9829 ½ºÆ®·¹ÀÎ ÃøÁ¤ DAQ
- ½ºÆ®·¹ÀÎ ¹× Àü¾Ð,Àü·ù,¿Âµµ,ÀúÇ×,½á¹Ì½ºÅÍµî ¸ÖƼÀÔ·Â 8ä³Î DAQ
 - Full-, Half-, Quarter- Bridge-Based ÃøÁ¤
- 24-Bit, 960Hz ADC »ùÇøµ - 500V °¥¹Ù´Ð Àý¿¬
- ¿ÜºÎ ºê¸®Áö ¹Ú½º¾øÀÌ ¸Å¿ì ½±°Ô ½ºÆ®·¹ÀΰÔÀÌÁö °á¼± 

           DT9829ÀÇ µ¿¿µ»óº¸±â

Key Features:
  • Direct connection of many types of sensors...software selectable per channel
    • Thermocouples: B, E, J, K, N, R, S, and T types
    • RTD: PT100, PT500, PT1000...2, 3, 4-wire
    • Thermistors
    • Bridge-based sensors: internal 3.0VDC excitation, ¡¾200mV input range
    • Voltage: ¡¾10V, ¡¾2V, ¡¾200mV input range
    • Current: ¡¾25mA
    • Resistance: 0 to 200k ohm
  • Each input channel independent...any sensor on any channel, no interaction
  • Sampling to 960 Hz
  • 24-bit Delta-Sigma ADC...eliminates aliasing for extremely accurate measurement
  • Thermocouple CJC and open circuit detection
  • 4 isolated digital inputs and digital outputs
  • ¡¾500V galvanic isolation...to PC and ground
  • USB 2.0 powered...no extra power supply needed
  • Terminal block connections
  • Supported by application software
   



  »óÈ£:  (ÁÖ)À妽ºÆ¼¿¥ I ÁÖ¼Ò: 16514, °æ±âµµ ¼ö¿ø½Ã ¿µÅ뱸 ¹ýÁ¶·Î 25, ±¤±³ SK VIEW Lake, Aµ¿ 1602È£ (³»¹æ°´: 24Ãþ ȸÀÇ½Ç »çÀü¿¹¾à)
  »ç¾÷ÀÚµî·Ï¹øÈ£: 214-03-16174  I  ´ëÇ¥ÀÚ: Á¶Àκ¹  I  ´ëÇ¥: 031-895-4370  
  Copyright @ 2000-2020 INDEXTM Corporation All Right Reserved
          º» ȨÆäÀÌÁöÀÇ ¹«´Üº¹Á¦¸¦ ºÒÇãÇÔ
           INDEXTM Corporation  A-1602, SK VIEW Lake Tower, 25, Beopjo-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16514, Korea.