Fully bi-directional four quadrants measurements for all energies and powers
Main electrical parameters measured and displayed for a cost-effective consumption analysis
Version for 1 or 5A CT and for direct connection up to 6A
Possibility to connect by PT
Up to 8 MB for data recording (ENH version)
Possibility to record all energy counters (ENH version)
Up to 24 parameters selectable among real time measurements for MIN/AVG/MAX recording (ENH version)
MODBUS RTU/ASCII communication by RS485 port or MODBUS TCP communication by Ethernet port
Possibility to manage the instrument in remote mode by WintoolNET software or by Web server interface
2 digital outputs, 1 digital input, 1 analog output (optional)
Applications
Energy audit.
Monitoring system and energy control.
Individual machine load monitoring.
Power peak control.
Switchboards, gensets, motor control centers, etc.
Remote metering and cost allocation.
Available Configurations
Basic
ENH
CURRENT INPUTS
For 1/5A CT
•
•
AUXILIARY POWER SUPPLY (make one choice only)
115 VAC ¡¾15% (only for instrument with RS485 port)
•
•
230 VAC ¡¾15% (only for instrument with RS485 port)
•
•
85...265 VAC (only for instrument with Ethernet port)
•
COMMUNICATION PORT (make one choice only)
RS485 for MODBUS RTU/ASCII communication
•
•
Ethernet for HTTP, MODBUS TCP communication
•
INSTRUMENT REMOTE MANAGEMENT
WintoolNET
•
•
Web server (only for instrument with Ethernet port)
•
SIGN REPRESENTATION IN MODBUS PROTOCOL (make one choice only)
Sign bit
•
•
2's complement
•
•
2 DIGITAL OUTPUTS
For alarm events or pulse emissions
•
•
ANALOG OUTPUT (only for instrument with RS485 port)
0...20 / 4...20 mADC, programmable
◦
DIGITAL INPUT
To synchronise the DMD value calculation
•
•
DMD VALUE CALCULATION MODE
Digital input synchronisation or Fixed window
•
Digital input synchronisation, Fixed or Sliding window
•
MEMORY
1 MB
•
8 MB
•
RECORDINGS
Active and reactive power AVG values
•
Real time params MIN/AVG/MAX values (up to 24 params programmable)
•
Energy counters
•
WIRING MODES
Three phase, 4 wires, 3 currents (3.4.3)
•
•
Three phase, 3 wires, 2 currents (3.3.2)
•
•
Single phase (1ph)
•
•
THD & HARMONICS
Voltage and current THD values
•
•
Voltage and current harmonics up to 15th
•
APPARENT ENERGY COUNTERS (make one choice only)
Total counters
•
•
Separated Inductive&Capacitive counters
•
•
Legend • = standard ◦ = optional
Specifications
Power supply Voltage range (according to the model): Instrument with RS485 port: 230 VAC ¡¾15% or 115 VAC ¡¾15% on request Instrument with Ethernet port: 85...265 VAC Frequency: 50/60 Hz
Voltage inputs
Maximum measurable voltage: 600 VAC max L-L Minimum voltage for FFT calculation: 20/35 VAC (multiplied by PT ratio in case of PT use) with direct connection Input impedance: ›1.3 MOhm Frequency: 45 - 65 Hz
Current inputs
Maximum value: 7 A Starting current (Ist): 2 mA CT burden: max 0.15 VA per phase Minimum current for FFT calculation: 100 mA * CT ratio
Typical accuracy Voltage: ¡¾0.2% reading in 10% FS...FS range (FS=Full Scale value) Current: ¡¾0.4% reading in 5% FS...FS range Power: ¡¾0.5% reading ¡¾0.1% FS (PF=1) Frequency: ¡¾0.1% reading ¡¾1 digit in 45...65 Hz range Active energy: Class 1 according to IEC/EN 62053-21 Reactive energy: Class 2 according to IEC/EN 62053-23
Display & keyboard Display: Backlighted LCD, 78x61 mm 3 rows, 4 digits + symbols Keyboard: 4 front buttons
Communication ports Type: RS485 optoisolated or Ethernet Protocols: MODBUS RTU/ASCII in case of RS485 port HTTP, NTP, DHCP, MODBUS TCP in case of Ethernet port Baud rate: 300 a 57600 bps in case of RS485 port 10/100 Mbps in case of Ethernet port
2 DIGITAL OUTPUTS (DO) Type: NPN or PNP, passive optoisolated Maximum values (according to IEC/EN 62053-31): 27 VDC - 27 mA Energy pulse length (only for DO in pulse mode): 50 ¡¾2ms ON time Max output reaction time (only for DO in alarm mode): 1 s
Environmental conditions Operating temperature: -25 ¡ÆC ... +55 ¡ÆC (3K6) Storage temperature: -25 ¡ÆC ... +75 ¡ÆC (2K3) Max humidity (without condensation): 80% Sinusoidal vibration amplitude: 50 Hz ¡¾0.075 mm Protection degree - frontal part: IP54 (granted only in case of installation in a cabinet with at least IP54 protection degree) Protection degree - terminals: IP20 Pollution degree: 2 Installation and use: Internal
Standard compliance (for the parts applicable for instrument) Directives: 2006/95/EC, 2004/108/EC Safety: EN 61010-1, EN 61010-2-030 EMC: EN 61326-1, EN 55011, EN 61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11, EN61000-6-2
Related products
Wintool WintoolNET
»óÈ£: (ÁÖ)À妽ºÆ¼¿¥ I ÁÖ¼Ò: 16514, °æ±âµµ ¼ö¿ø½Ã ¿µÅ뱸 ¹ýÁ¶·Î 25, ±¤±³ SK VIEW Lake, Aµ¿ 1602È£ (³»¹æ°´: 24Ãþ ȸÀÇ½Ç »çÀü¿¹¾à) »ç¾÷ÀÚµî·Ï¹øÈ£: 214-03-16174 I ´ëÇ¥ÀÚ: Á¶Àκ¹ I ´ëÇ¥: 031-895-4370 Copyright @ 2000-2020 INDEXTM Corporation All Right Reserved º» ȨÆäÀÌÁöÀÇ ¹«´Üº¹Á¦¸¦ ºÒÇãÇÔ INDEXTM Corporation A-1602, SK VIEW Lake Tower, 25, Beopjo-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16514, Korea.