QM-100 ¼¾¼­,º¯È¯±â,¹ÌÅÍ, ÄÁÆ®·Ñ·¯ ÅëÇÕ

ProSens´Â ¼¾¼­, º¯È¯±â, ¹ÌÅÍ ¹× ÄÁÆ®·Ñ·¯ ±â´ÉÀ» ÅëÇÕÇÑ »ê¾÷ ±â±âÀÇ »õ·Î¿î ½Ã¸®ÁîÀÔ´Ï´Ù.
Åë½ÅÆ÷Æ®´Â RS-485 ¸ðµå ¹ö½º ÇÁ·ÎÅäÄݻӸ¸ ¾Æ´Ï¶ó, µÎ °³ÀÇ µ¶¸³ÀûÀÎ ¹ü¿ë ÀÔ·Â, µÎ°³ÀÇ ¹ÙÀ̳ʸ® ¶Ç´Â ¾Æ³¯·Î±× Ãâ·ÂÀ» °¡Áý´Ï´Ù.
¸ðµ¨ QM-100Àº ÇÁ·Îºê°¡ ¾ø´Â ¹öÀüÀÔ´Ï´Ù.
Ãâ·Â½ÅÈ£´Â ProSens Á¦¾î½Ã½ºÅÛÀÇ ÀÀ¿ëÇÒ ¼öÀÖ½À´Ï´Ù.
ProSens µ¶¸³Çü ÄÁÆ®·Ñ·¯·Î »ê¾÷¿ë ¾ÖÇø®ÄÉÀ̼ǿ¡ Àû¿ëµÉ ¼öÀÖ½À´Ï´Ù.
¶ÇÇÑ, Modbus ÇÁ·ÎÅäÄÝÀ» ÅëÇØ ¸¶½ºÅÍ µð¹ÙÀ̽º¸¦ »ç¿ëÇÏ¿© ºÐ»ê ¸ð´ÏÅ͸µ½Ã½ºÅÛ ¹× ³×Æ®¿öÅ©¸¦ ±¸ÃàÇÒ ¼öÀÖ½À´Ï´Ù.

 

ProSens - new quality in measurements

Data acquisition systems for environmental monitoring and control support the production processes to ensure high quality services over the years. To meet these needs, we developed a new line of industrial ProSens instrumentation, integrating the functionality of sensors, transmitters, meters and controllers.

 

ProSens

 

For details on specific devices included in the ProSens line please go to subdirectory Humidity and temperature indicators / controllers and to brochure.

 

ProSens

  • 1 or 2 measuring channels available, with or without a probe
  • Integrated or cable probes made of 316L steel, used for temperature or temperature and humidity measurements
  • Universal inputs of a very wide spectrum of analogue signal types (I, U, RTD, TC)
  • Binary and analogue outputs for indicating and controlling (1 or 2 E REL, I, U)
  • Very clear 2.9¡¯¡¯ LCD display
  • Standard equipment: RS-485 Modbus RTU interface for integration with superordinate visualisation or control systems
  • Device configuration performed by means of local buttons, optional remote controller or free S-Config 2 software



    Parameters

    Àü¿ø°ø±Þ 24V DC (11 ¡À 36V DC); for versions with voltage output min. 16V DC
    ÇÁ·çºêŸÀÔ none
    ÃøÁ¤·¹ÀÎÁö current: 0/4-20 mA; voltage: 0/1-5 V, 0/2-10V, 0-60 mV, 0-75 mV, 0-100 mV, 0-150 mV; RTD: Pt100, Pt500, Pt1000, measuring range: -100¡ÆC ¡À 600¡ÆC; thermocouple: type K, S, J, T, N, R, B, E; measuring ranges: -200¡ÆC ¡À +1370¡ÆC (K); -50¡ÆC ¡À +1768¡ÆC (S); -210¡ÆC ¡À +1200¡ÆC (J); -200¡ÆC ¡À +400¡ÆC (T); -200¡ÆC ¡À +1300¡ÆC (N); -50¡ÆC ¡À +1768¡ÆC (R); +250¡ÆC ¡À +1820¡ÆC (B); -200¡ÆC ¡À +1000¡ÆC (E)
    Àü·Â¼Ò¸ð  max. 2,5 W
    ÀԷ½ÅÈ£  1 or 2 universal: current; voltage; RTD; thermocouple K, S, J, T, N, R, B, E types
    ¹ÙÀ̳ʸ® Ãâ·Â 0, 1 or 2 electronic NO relays, 24V AC/35V DC, max. 200 mA
    ¾Æ³¯·Î±× Ãâ·Â  active current: operating range 0/4-20 mA (max. 0-24 mA), load resistance 700 ¥Ø max., resolution 13 bit; passive current: isolated, operating range 4-20 mA (max. 2,8-24 mA), load resistance 600 ¥Ø@24VDC, resolution 13 bit; active voltage: operating range 0/1-5V, 0/2-10V (max. 0-11V), load resistance min. 2000 ¥Ø, resolution 13 bit
    Åë½Å RS-485, 8N1 and 8N2, 1200 bit/s ¡À 115200 bit/s, Modbus RTU, not galvanically isolated
    »ç¿ë¿Âµµ -30¡ÆC ¡À +80¡ÆC, case with electronics (out of range -20 ¡À +70¡ÆC LCD and IR receiver turn off)
    Á¤È®µµ accuracy: 0.1% @25¡ÆC ¡¾ one digit (inputs: current, voltage, milivoltage, thermoresistance, thermocouple K, J, E); 0.2%@ 25¡ÆC (thermocouple N), 0.5%@25¡ÆC (thermocouple S, T, R, B)
    ÄÉÀ̽º ÀçÁú ASA LURAN
    ÄÉÀ̽º wall mounted
    Å©±â 120 x 90 x 50 mm
    º¸È£ IP 67 (version without display); IP 65 (version with display)
    È­¸é
    optionally: graphic LCD, 128 x 64 points, with backlight
    ¿Âµµ¾ÈÁ¤¼º:  typ. 50 ppm/¡ÆC
                                                             


    Option configurator

    Product code:
    Measurement 1: universal input (I, U, RTD, TC) - without probe
    ------------------------------------------------------------
    Measurement 2: none
    Measurement 2: universal input (I, U, RTD, TC)
    ------------------------------------------------------------
    Output: none
    Output: 2 x E REL
    Output: 1 x AO (0/4-20 mA, active, non-isolated) + 1 x E REL
    Output: 1 x AO (4-20 mA, passive, isolated) + 1 x E REL
    Output: 1 x AO (0-10V, active, non-isolated) + 1 x E REL
    Output: 2 x AO (0/4-20 mA, active, non-isolated)
    Output: 2 x AO (4-20 mA, passive, isolated)
    Output: 2 x AO (0-10V, active, non-isolated)
    ------------------------------------------------------------
    Display: none
    Display: LCD, 128 x 64 pixels
    ------------------------------------------------------------
    Communication interface: RS-485 / Modbus RTU (10)
    ------------------------------------------------------------
    Power supply: 24V DC
    ------------------------------------------------------------
    The number of available glands: 3 pcs
    The number of available glands: 4 pcs
    The number of available glands: 5 pcs
  •    



      »óÈ£:  (ÁÖ)À妽ºÆ¼¿¥ I ÁÖ¼Ò: 16514, °æ±âµµ ¼ö¿ø½Ã ¿µÅ뱸 ¹ýÁ¶·Î 25, ±¤±³ SK VIEW Lake, Aµ¿ 1602È£ (³»¹æ°´: 24Ãþ ȸÀÇ½Ç »çÀü¿¹¾à)
      »ç¾÷ÀÚµî·Ï¹øÈ£: 214-03-16174  I  ´ëÇ¥ÀÚ: Á¶Àκ¹  I  ´ëÇ¥: 031-895-4370  
      Copyright @ 2000-2020 INDEXTM Corporation All Right Reserved
              º» ȨÆäÀÌÁöÀÇ ¹«´Üº¹Á¦¸¦ ºÒÇãÇÔ
               INDEXTM Corporation  A-1602, SK VIEW Lake Tower, 25, Beopjo-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16514, Korea.